            | TR-668 
                Electronic Load Syetem  | 
           
            |  | 
           
            |  | 
           
            |  | 
           
            |  |  | 
           
            |  SPECIFICATIONS£º | 
           
            |  | 
           
            |  60V ¡¢60A¡¢ 300W | 
           
            |  Stable 
              current,resistance,voltage,power | 
           
            |  4  Display Voltage¡¢Current¡¢Resistance¡¢Power. | 
           
            |  40 group 
              memory,operable by 1 or 40 module simultanously. | 
           
            |  C.C mode 
              provide static & dynmaic test function. | 
           
            |  Input voltage limit setting & judgement. | 
           
            | Click for detail |  | 
           
            |  | 
           
            |  PARAMETERS£º£¨15¡æ~35¡æ£¬RH¡Ü75%£© | 
           
            | 
                 
                  | Model |  |   
                  | Rating | Operating voltage Current
 Power
 Min. operating start voltage
 | 1~60V60A
 300W
 1.5V
 |   
                  | CC Mod | Operating range | H range | 0~60A |   
                  | L range | 0~60A |   
                  | Setting accuracy | ¡À(0.3%¡À20mA) |   
                  | Setting resolution | H range | 1mA |   
                  | L range | 1mA |   
                  | CR Mode | Operating range | H range | 0.05¦¸~4K¦¸ |   
                  | L range | 0.05¦¸~4K¦¸ |   
                  | Setting accuracy | H range | 1m¦¸ |   
                  | L range | 1m¦¸ |   
                  | Setting accuracy | ¡À(0.5% +20m¦¸) |   
                  | CV Mode | Operating range | 0~60V |   
                  | Setting accuracy | ¡À(0.5% +10mV) |   
                  | Setting resolution | 1 mV |   
                  | CP Mode | Operating range | 0~300W |   
                  | Setting accuracy | ¡À(0.2% +10mW) |   
                  | Setting resolution | 1 mW |   
                  | Dynamic Operation
 CC Mode
 only
 | T high, T low | 20¦ÌS~9999sec |   
                  | Slew rate | H range | 1mA~2.5A/¦ÌS |   
                  | L range | 1mA~2.5A/¦ÌS |   
                  | Accuracy | ¡À5% |   
                  | Voltage | Accuracy |  | ¡À(0.1% +10mV) |   
                  | Read- back | Resolution | H range | 0.01V |   
                  |  |  | L range | 0.001V |   
                  | Current Read- back
 | Accuracy | ¡À(0.3% +20mA) |   
                  | Resolution | H range | 0.01A |   
                  | L range | 0.001A |   
                  | Current Monitor
 | Full scale output voltage | 10V/60A |   
                  | Accuracy | ¡À(2% +100mV) |   
                  | Short Test
 | Function | Built-in with short current indicate |   
                  | Short Current Indicate | 60A |   
                  | Accuracy | ¡À(2% +100mA) |   
                  | Memory£º40 Set test parameter 
                    store, recall function |   
                  | Power consumption£º100W max. |   
                  | Power requirement£º115VAC(105~125V) 
                    or 230VAC (210~250V) 50/60Hz |   
                  | Operating temp£º0¡æ~40¡æ |   
                  | Mechanical size£º 110(W) ¡Á440(D) 
                    ¡Á177(H)mm |   
                  | Option£º©~ GPIB 
                    Function: SH1, AH1, T8, L4, RL2 ©~Switching power supply Test 
                    fixture Special order for large capacity load 
                    is possible
 |  | 
           
            |  |