TR-668R Electronic
load tester
|
|
|
|
|
|
Characteristic£º |
|
4 of 300W
module unit£º60V¡¢60A¡¢300W ¡Á4 |
The module
from various places can be carried out alone: the stable electric
current; |
___the stable voltage, the stable
resistance, the stable power mode; |
4 load
module unit can connect by sereis/parallel |
4 module
the operate function like TR-668; |
Take one GPIB address only , can remote control all (options) |
|
Click for detail |
|
|
Technic
index £º£¨15¡æ~35¡æ£¬RH¡Ü75%£© |
Model |
|
Rating |
Operating voltage
Current
Power
Min. operating start voltage |
1~60V
60A
300W
1.5V |
CC Mod |
Operating range |
H range |
0~60A |
L range |
0~60A |
Setting accuracy |
¡À(0.3%¡À20mA) |
Setting resolution |
H range |
1mA |
L range |
1mA |
CR Mode |
Operating range |
H range |
0.05¦¸~4K¦¸ |
L range |
0.05¦¸~4K¦¸ |
Setting accuracy |
H range |
1m¦¸ |
L range |
1m¦¸ |
Setting accuracy |
¡À(0.5% +20m¦¸) |
CV Mode |
Operating range |
0~60V |
Setting accuracy |
¡À(0.5% +10mV) |
Setting resolution |
1 mV |
CP Mode |
Operating range |
0~300W |
Setting accuracy |
¡À(0.2% +10mW) |
Setting resolution |
1 mW |
Dynamic
Operation
CC Mode
only |
T high, T low |
20¦ÌS~9999sec |
Slew rate |
H range |
1mA~2.5A/¦ÌS |
L range |
1mA~2.5A/¦ÌS |
Accuracy |
¡À5% |
Voltage |
Accuracy |
|
¡À(0.1% +10mV) |
Read- back |
Resolution |
H range |
0.01V |
|
|
L range |
0.001V |
Current
Read- back |
Accuracy |
¡À(0.3% +20mA) |
Resolution |
H range |
0.01A |
L range |
0.001A |
Current
Monitor |
Full scale output voltage |
10V/60A |
Accuracy |
¡À(2% +100mV) |
Short
Test |
Function |
Built-in with short current indicate |
Short Current Indicate |
60A |
Accuracy |
¡À(2% +100mA) |
Memory£º40 Set test parameter
store, recall function |
Power consumption£º100W max. |
Power requirement£º115VAC(105~125V)
or 230VAC (210~250V) 50/60Hz |
Operating temp£º0¡æ~40¡æ |
Mechanical size£º 110(W) ¡Á440(D)
¡Á177(H)mm |
Option£º©~ GPIB
Function: SH1, AH1, T8, L4, RL2 ©~Switching power supply Test
fixture Special order for large capacity load
is possible |
|
|