Model |
|
Rating |
Operating voltage
Current
Power
Min. operating start voltage |
1~300V
10A
300W
1.5V |
CC Mod |
Operating range |
H range |
1~10A |
L range |
1~10A |
Setting accuracy |
±(0.3%±20mA) |
Setting resolution |
H range |
1mA |
L range |
1mA |
CR Mode |
Operating range |
H range |
0.5Ω~9.999KΩ |
L range |
0.5Ω~9.999KΩ |
Setting accuracy |
H range |
1mΩ |
L range |
1mΩ |
Setting accuracy |
±(0.5% +20mΩ) |
CV Mode |
Operating range |
0~300V |
Setting accuracy |
±(0.5% +10mV) |
Setting resolution |
1 mV |
CP Mode |
Operating range |
0~300W |
Setting accuracy |
±(0.2% +10mW) |
Setting resolution |
1 mW |
Dynamic
Operation
CC Mode
only |
T high, T low |
20μS~9999sec |
Slew rate |
H range |
1mA~9.999A/μS |
L range |
1mA~9.999A/μS |
Accuracy |
±5% |
Voltage |
Accuracy |
|
±(0.1% +10mV) |
Read- back |
Resolution |
H range |
0.01V |
|
|
L range |
0.001V |
Current
Read- back |
Accuracy |
±(0.3% +20mA) |
Resolution |
H range |
0.01A |
L range |
0.001A |
Current
Monitor |
Full scale output voltage |
10V/60A |
Accuracy |
±(2% +100mV) |
Short
Test |
Function |
Built-in with short current indicate |
Short Current Indicate |
10A |
Accuracy |
±(2% +100mA) |
Memory:40 Set test parameter
store, recall function |
Power consumption:100W max. |
Power requirement:115VAC(105~125V)
or 230VAC (210~250V) 50/60Hz |
Operating temp:0℃~40℃ |
Mechanical size: 110(W) ×440(D)
×177(H)mm |
Option:﹡ GPIB
Function: SH1, AH1, T8, L4, RL2 ﹡Switching power supply Test
fixture Special order for large capacity load
is possible |